Nova Publishers
My Account Nova Publishers Shopping Cart
HomeBooksSeriesJournalsReference CollectionseBooksInformationSalesImprintsFor Authors
            
  Top » Catalog » Books » Most recent entries » My Account  |  Cart Contents  |  Checkout   
Quick Find
  
Use keywords to find the product you are looking for.
Advanced Search
What's New? more
Urban Planning and Renewal
$95.00
Shopping Cart more
0 items
Information
Shipping & Returns
Privacy Notice
Conditions of Use
Contact Us
Bestsellers
01.Sociology of Interprofessional Health Care Practice: Critical Reflections and Concrete Solutions
02.Precision Gear Shaving
03.The Law of Science and the Science of Law: Cases in Forensic Science
04.Social Capital
05.Sex Chromosomes: Genetics, Abnormalities, and Disorders
06.Problem Solving with Delphi - CD included
07.Suicide and the Creative Arts
08.Taliban in Pakistan: A Chronicle of Resurgence
09.Textbook of Therapeutic Cortical Stimulation
10.Seabed Morphology of the Russian Arctic Shelf
Notifications more
NotificationsNotify me of updates to Surface Modified Biochemical Titanium Alloys
Tell A Friend
 
Tell someone you know about this product.
Surface Modified Biochemical Titanium Alloys
Retail Price: $59.00
10% Online Discount
You Pay:

$53.10
Authors: Aravind Vadiraj, (Advanced Engineering, Ashok Leyland Technical Center, Vellivoyalchavadi, Tamilnadu, India) M . Kamaraj ( Indian Institute of Technology, Madras Chennai, Tamilnadu, India) 
Book Description:
Load bearing implants such as hip joints, knee joints and bone plates etc. are prone to failure from the conjoint effect of wear, fretting and corrosion from the movement of body. Modular junctions of hip implants consist of ball on a shaft which is under sliding conditions during body movements like walking etc. Fretting is experienced at ball and shaft contact. Fretting wear or fretting fatigue is a form of adhesive wear phenomenon wherein a small tangential oscillatory motion under certain contact pressure gradually erodes the surface and initiates crack within the contact leading to ultimate failure of the material under fatigue loading condition. Titanium alloys, Stainless steels and Co-Cr-Mo alloys are most commonly used for medical grade devices. Titanium alloys has high strength to weight ratio, superior biocompatibility and corrosion resistance compare to other materials. Fretting fatigue life of surface modified titanium alloys has improved compared to unmodified materials due to enhancement in surface properties and reduction in friction.

We’ve partnered with Copyright Clearance Center to make it easy for you to request permissions to reuse Nova content.
For more information, click here or click the "Get Permission" button below to link directly to this book on Copyright Clearance Center's website.


Table of Contents:
Abstract

Chapter 1. Introduction, pp. 1-5

Chapter 2. Literature Survey, pp. 7-36

Chapter 3. Objectives And Scope, pp. 37-39

Chapter 4. Experimental Conditions, pp. 41-50

Chapter 5. Results And Discussion, pp. 51-108

Chapter 6. Conclusions, pp. 109-116

References pp.117-124

Index pp.125-132

   Series:
      Materials Science and Technologies
   Binding: Softcover
   Pub. Date: 2010
   Pages: 132.pp
   ISBN: 978-1-60876-581-2
   Status: AV
  
Status Code Description
AN Announcing
FM Formatting
PP Page Proofs
FP Final Production
EP Editorial Production
PR At Prepress
AP At Press
AV Available
  
Customers who bought this product also purchased
Fire Safety
Fire Safety
Air Quality in the 21st Century
Air Quality in the 21st Century
Special Education in the 21st Century
Special Education in the 21st Century
Electric Vehicles: Technology, Research and Development
Electric Vehicles: Technology, Research and Development
Sovereign Wealth Funds
Sovereign Wealth Funds
Hazardous Waste: Classifications and Treatment Technologies
Hazardous Waste: Classifications and Treatment Technologies
Special Focus Titles
01.Medical Cannabis: Clinical Practice
02.Hemorrhagic Shock: Recognition, Pathophysiology and Management
03.Patellofemoral Pain: An Evidence-Based Clinical Guide
04.Neanderthals in Plato’s Cave: A Relativistic Approach to Cultural Evolution
05.My Patients Were Mummies
06.‘L’Atelier Moderne’: An Exploration of the Collaborative Process Between Performer and Composer in Vocal Music Theatre of the 21st Century (CD Included)
07.The Voice at the End of the Telephone Line: The Psychology of Tele Carers
08.Caught up in the Spirit! Teaching for Womanist Liberation
09.The Transgender Handbook: A Guide for Transgender People, Their Families and Professionals
10.Mastering Science with Metacognitive and Self-Regulatory Strategies: A Teacher-Researcher Dialogue of Practical Applications for Adolescent Students
11.Political Migrations in Poland in the Period of World War II
12.Sociolinguistic Parallels Across Europe: Focus on Lowland Scotland and the Eastern Slavic Countries

Nova Science Publishers
© Copyright 2004 - 2017

Surface Modified Biochemical Titanium Alloys